Summary: NUT blazer_usb ippon_command stack info-leak via unzeroed char tmp[64] in OUT-direction usb_control_msg

EPSS: 0.2% probability of exploitation in the next 30 days (percentile 4.3).

Details

Network UPS Tools is a collection of programs which provide a common interface for monitoring and administering UPS, PDU and SCD hardware. From 2.4.2 through 2.8.5, ippon_command in drivers/blazer_usb.c partially initializes char tmp[64] with a short Megatec status query and then passes a fixed eight-byte chunk to usb_control_msg. A malicious firmware-controlled USB device presenting the Mustek Powermust VID 0x06da and Mustek Powermust PID 0x0003 matches blazer_usb_id, selects ippon_subdriver, and can receive the uninitialized trailing stack bytes during normal polling. The disclosure is bounded and read-only, requires physical or supply-chain access to the USB bus, and has no established integrity or availability impact. This issue is scheduled to be fixed in version 2.8.6.

Severity

LOW (CVSS 2.4) — vector CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N